Written answer
State Properties
The 182.07 kWh/m² figure came from a 2024 Display Energy Certificate based on meter readings and expresses benchmarked primary energy.
43. Deputy Ken O'Flynn asked the Minister for Public Expenditure, Infrastructure, Public Service Reform and Digitalisation the basis on which the pre-retrofit energy performance figure of 182.07 kWh per square metre per year for Áras an tSáile, Renmore, Galway, was calculated, including whether it represents primary or delivered energy; whether it was modelled or based on metered consumption, given that metered consumption reported by the Department of Defence was 394,173.84 kWh in 2024 for a gross internal floor area of 4,508.93 square metres; and if he will make a statement on the matter. [77994/26]
Comment on this
The pre-retrofit energy performance figure of 182.07 kWh per square metre per year for Áras an tSáile, Renmore, Galway, was calculated from the Display Energy Certificate issued by a registered BER assessor on 25 July 2024. It was based on a useful floor area of 4,157 sq m. The BER is based on the meter readings for all energy used in the building. The BER and CO2 indicators are expressed as ratios of primary energy and CO2 emissions relative to a benchmark that represents the performance of all buildings of this type. SEAI provides guidance on how all BERs are calculated. This building type is classified as a General office and is categorised as a building environment of Heating and Natural ventilation.